Mass Flow Units
Overview and Key Concepts
Mass flow units, or just flow units, are the elements whose flow is simulated by mass flow conveyors. In FlexSim, mass flow conveyors use a fluid-like algorithm for calculating product flow. Using this algorithm enables significant simulation performance improvements. Whereas the algorithm represents a computational simplification, in real life, mass flow conveyors convey actual discrete objects like bottles, cans, crackers, cookies, cartons, etc. The flow unit in FlexSim provides the data necessary to translate between these discrete objects and the fluid-like algorithm that simulates their flow in FlexSim.
The primary simulation-defining properties of the flow unit are its Length, Width, and Round Shape. Using these attributes, the simulation can resolve the maximum possible density of units on a conveyor. These densities are the actual things that flow down conveyors, instead of individual units. Using the calculated max density, each conveyor can calculate flow rates based on the conveyor's width and speed.
The other attributes of the flow unit are for rendering purposes. They define how the units should be drawn on the conveyor.
Properties
The Mass Flow Unit Properties window has the following properties:
Length
The length of a unit. This corresponds to the space taken up by a single unit, along the conveyor's forward axis. If you are simulating bottles, this would be the diameter of the bottle. If you are simulating a non-symmetric object like, say, crackers, this should be the amount of forward-axis space the cracker takes up when accumulated on the conveyor.
Width
The width of a unit. This corresponds to the space taken up by a single unit, along the conveyor's left-right axis. If you are simulating bottles, this would be the diameter of the bottle. If you are simulating a non-symmetric object like, say, crackers, this should be the amount of left-right-axis space the cracker takes up.
Height
The height of a unit. This is only used for drawing purposes, and defines the height at which units, bars, etc. are drawn on the conveyor.
Round Shape
Defines whether the unit's shape is round. When this is checked, the maximum density of the unit will be calculated higher, as round shapes like bottles will pack together using a hexagonal, as opposed to a square, pattern. This also causes units to be drawn on the conveyor using this hexagonal pattern.
Draw Mode
Defines how the various densities will be drawn on the conveyor. One of the following values is possible:
- Shapes - Ihe units will be drawn as individual shapes. Note that it does not acually simulate/track individual units. It merely draws a number of units based on the density unit density at a give point on the conveyor. This setting is also further configured with the Fill Order property, explained below.
- Bars - Ihe densities will be drawn as bars that flow along the conveyor. This setting is also further configured with the Fill Order property, described below.
Shape Item
When Draw Mode is defined as Shapes, this defines the shape to be drawn. You can statically define one of the flow items, or you can dynamically define different shapes based on things like densities, etc.
Fill Order
Defines how different densities will "fill up" the conveyor when drawn. This is dependent on the Draw Mode. The following table demonstrates the different property combinations, and how they will be drawn.
Shapes | Bars | |
---|---|---|
Length then Width | ||
Width then Length |